Calculated-industries 6260 User Guide Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Nástroje Calculated-industries 6260 User Guide. Calculated Industries 6260 User Guide User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1

USER’SGUIDEAreaTake - Off Tooland Digitizing SystemModel#6260

Strany 2 - TABLE OF CONTENTS

GETTING STARTEDOnce assembly and setup are complete, proceed with the following steps in order to begin measuring.1. When placing the bars and securin

Strany 3 - INTRODUCTION

Right-Hand Confi guration ShownUSER’S GUIDE — 9

Strany 4 - PACKAGE CONTENTS

[END] Ends polyline measurement, displaying the total perimeter. Also ends the 2-Point Circle measurement when measuring a diameter, displaying the ci

Strany 5 - USER’S GUIDE — 3

[ON/CLEAR]Turns the unit ON and clearsthe display. Holding down the[ON/CLEAR] key for 1.5 seconds also powers the unit off. [CLOSE +]Completes the Pol

Strany 6 - RIGHT-HAND ASSEMBLY

[UNDO]Undoes the previous measurement. Allows you to undo the last 10 measurements (if applicable) while in measure mode. If a measurement has been cl

Strany 7 - FINAL ASSEMBLY

[PC SEND]When connected to a PC, sends the value on the main display in decimal format to the PC (see PC Interface section). [ARC/CIRC]First press ide

Strany 8 - LEFT-HAND ASSEMBLY

[MODE]Used to select from the list of available modes (see Built-In Scales section).[SET] [MODE]Used to move back through the list of available modes.

Strany 9

[UNITS]Used to select from the list of available units of measurement (see Units of Measurement section).[SET] [UNITS]Used to move back through the li

Strany 10 - GETTING STARTED

The top legend displays the following:• SET• CIRC (Circle)• ARC• M (Memory)The Measure Status and number of sides are displayed here (End or Closed a

Strany 11 - USER’S GUIDE — 9

BUILT-IN SCALESThe following modes and scales are available for selection using the [MODE] and [SCALE] keys, depending on whether the puck is set to I

Strany 12 - KEY DEFINITIONS

TABLE OF CONTENTS INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1SETUP . . . . . . . . . . . . . . . . . . .

Strany 13 - USER’S GUIDE — 11

SHAPES AND DEFINITIONSThe Ultra Scale Master Pro can measure Polylines, Polygons, regular or irregular shapes, Arcs and Circles based on the following

Strany 14 - FUNCTION KEYS

IRREGULAR SHAPEAn outline orsurface confi gurationof a formARC:A segment of a curveCIRCLE:A plane curve equidistant from a fi xed centerILLEGAL SHAPE:Th

Strany 15 - USER’S GUIDE — 13

12MEASURING POLYLINESOPERATING SEQUENCE1. Press the [ON/CLEAR] key twice to clear the display. Place the crosshairs over the fi rst point and press the

Strany 16 - SETUP KEYS

PERIMETERWALL AREA*HEIGHT*SIDE 1SIDE 24. Press the [END] key. The total Perimeter is displayed. Once a measurement is ended, press the D-Pad down [6]

Strany 17 - USER’S GUIDE — 15

MEASURING SIMPLE POLYGONSOPERATING SEQUENCE1. Press the [ON/CLEAR] key twice to clear the display. Place the crosshairs over the fi rst point and press

Strany 18 - UNDERSTANDING THE LCD

5. Press the [CLOSE+] key. The total Area is displayed. Once a measurement is closed, press the D-Pad down [6] to display Perimeter, Wall Area, Volume

Strany 19 - Modes Scales

MEASURING TAKE-OUTSOPERATING SEQUENCE1. Press the [ON/CLEAR] key twice to clear the display. Place the crosshairs over the fi rst point and press the [

Strany 20 - POLYLINE:

AREAADJUSTED AREA5. Press the [CLOSE+] key. The total Area is displayed.*6. Press the [M+] key to store the Area in Memory, then repeat steps 1 throug

Strany 21 - ILLEGAL SHAPE:

MEASURING COMPLEX POLYGONSOPERATING SEQUENCE1. Press the [ON/CLEAR] key twice to clear the display. Place the crosshairs over the fi rst point and pres

Strany 22 - MEASURING POLYLINES

AREAPERIMETERWALL AREA*HEIGHT*VOLUME*SIDE 1SIDE 2SIDE 3SIDE 5SIDE 4SIDE 6SIDE 8SIDE 79. Press the [CLOSE+] key. The total Area is displayed. Once a me

Strany 23 - USER’S GUIDE — 21

INTRODUCTION The Ultra Scale Master Prohas been specifi cally designed for residential and light commercial builders and contractors requiring area and

Strany 24 - MEASURING SIMPLE POLYGONS

MEASURING IRREGULAR SHAPESOPERATING SEQUENCE1. Press the [ON/CLEAR] key twice to clear the display. Place the crosshairs over the fi rst point and pres

Strany 25 - USER’S GUIDE — 23

AREAPERIMETERWALL AREA*HEIGHT*VOLUME*SIDE 1SIDE 2SIDE 3SIDE 5SIDE 4SIDE 6SIDE 8SIDE 79. Press the [CLOSE+] key. The total Area is displayed. Once a me

Strany 26 - MEASURING TAKE-OUTS

MEASURING ARCS AND CIRCLESDEFINITIONS: Listed below are defi nitions and illustrations of the Arc and Circle measurement results.ARC AREACHORD LENGTHCH

Strany 27 - ADJUSTED AREA

CIRCLE PERIMETERCIRCLE AREAHEIGHTCIRCLE PERIMETERCIRCLE AREACIRCLE DIAMETERCIRCLERADIUSHEIGHTCircle Volume – The total of the Circle Area multiplied b

Strany 28 - MEASURING COMPLEX POLYGONS

MEASURING ARCSOPERATING SEQUENCE1. Press the [ON/CLEAR] key twice to clear the display. Press the [ARC/CIRC]* key once to enter Arc Mode. Place the cr

Strany 29

ARC LENGTHARC LENGTH WALL AREAARC AREAARC PERIMETERARC WALL AREA*ARC HEIGHT*ARC VOLUME*4. Upon pressing the [MEASURE] key in Step-3, the Arc measureme

Strany 30 - MEASURING IRREGULAR SHAPES

MEASURING 3-POINT CIRCLESOPERATING SEQUENCE11. Press the [ON/CLEAR] key twice to clear the display. Press the [ARC/CIRC]* key twice to enter Circle Mo

Strany 31

CIRCLE RADIUSCIRCLE DIAMETER4. Upon pressing the [MEASURE] key in Step 3, the Circle measurement was automatically completed and the Circle Area displ

Strany 32 - MEASURING ARCS AND CIRCLES

There are two methods for programming Custom Scales into your Ultra Scale Master Pro. “Measured Custom Scales” allow you to measure a specifi ed Length

Strany 33 - USER’S GUIDE — 31

5. The displayed units begin fl ashing, indicating that they are ready to be changed. Press [UNITS] to scroll through the available units.*6. Press D-P

Strany 34 - MEASURING ARCS

SETUPPACKAGE CONTENTSYour package contains the following pieces:Female End Cap2 — ULTRA SCALE MASTER® PROLong Refl ector BarUSB CableUltra Scale Master

Strany 35 - USER’S GUIDE — 33

SETTING AN ENTERED CUSTOM SCALE (IMPERIAL MODE)1. Press [MODE] until “CUST” is displayed. Press [SCALE] to scroll through the four available Custom Sc

Strany 36 - MEASURING 3-POINT CIRCLES

A Height can be set to calculate Wall Areas and Volumes which are displayed using the D-Pad once an area measurement has been completed. If no Height

Strany 37 - USER’S GUIDE — 35

UNITS OF MEASUREMENTThe following units of measurement are available for selection by pressing the [UNITS] key located under the slide cover door. You

Strany 38 - CUSTOM SCALES

DIGITIZER MODEThe Ultra Scale Master Pro can be used as a Digitizer to send measurement data (X,Y coordinates) and key press data to digitizing softwa

Strany 39 - USER’S GUIDE — 37

PC INTERFACEThe Ultra Scale Master Pro with PC Interface can be used to send displayed numerical values from your Puck directly to the selected estima

Strany 40 - 38 — ULTRA SCALE MASTER

SENDING VALUES TO YOUR PC (PC SEND) The [PC Send] key sends the displayed value from the Puck to the selected software program on your PC. Values can

Strany 41 - SETTING A HEIGHT

The following is an example of the results of a Polygon measurement, which include the Area, Perimeter, Wall Area, and Volume.In the fi rst column are

Strany 42 - VOLUME UNITS

1. MEASUREMENT DISPLAY:Total* – Displays the accumulated total of all measured segments.Side – Displays only the last measured segment.2. BEEP:On*

Strany 43 - DIGITIZER MODE

5. PC SEND TERMINATING COMMAND:Enter* – Performs an ENTER command after value is sent to the PC.Tab – Performs a TAB command after value is sent to

Strany 44 - PC INTERFACE

APPENDIX A APPENDIX BACCURACY/ERRORS/AUTO SHUT-OFFAccuracy/Display Capacity – The Ultra Scale Master Prohas a seven-digit main display, while maintai

Strany 45 - USER’S GUIDE — 43

User’s Guide,Quick Reference Guide,and Quick Setup SheetMale End CapUSER’S GUIDE — 3Short Refl ector BarLong Refl ector BarCarrying Case

Strany 46 - 44 — ULTRA SCALE MASTER

APPENDIX C APPENDIX DSPECIFICATIONS REPAIR AND RETURNWARRANTY, REPAIR AND RETURN INFORMATIONReturn Guidelines1. Please read the Warranty in this User

Strany 49 - APPENDIX A APPENDIX B

RIGHT-HAND ASSEMBLYAssemble the refl ector bars as shown. Align the corner connector at a 90° angle at the top left corner of the plans.5. Slide Female

Strany 50 - APPENDIX C APPENDIX D

4. Insert the Male End Cap into the female end of the Short Refl ector Bar. The Male End Cap is preinstalled for a Right-Hand confi guration.3. Insert t

Strany 51

NOTE: Sloping side of the Refl ector Bars face outward.5. Insert the the male end of the second Long Refl ector Bar into the female end of the Short Refl

Strany 52

FINAL ASSEMBLYThe ultrasonic beams are sent from the right arm of the Puck to the top bar, then refl ected back, and from the left arm of the Puck to t

Komentáře k této Příručce

Žádné komentáře